Uniformly Distributed Loads (UDL)
All rated beam capacities assume evenly distributed static loads across the pair of beams, with each beam safely supporting exactly 50% of the total shelf weight.
Comprehensive engineering load capacity specifications for roll-formed step beams, structural steel channels, and upright frames.
At Plata Metal Shelving S.A., all pallet rack load capacities are calculated in strict compliance with the latest Rack Manufacturers Institute (RMI) ANSI MH16.1 specifications and the AISI Cold-Formed Steel Design Manual utilizing Load and Resistance Factor Design (LRFD) methodology.
All rated beam capacities assume evenly distributed static loads across the pair of beams, with each beam safely supporting exactly 50% of the total shelf weight.
Beam load ratings strictly adhere to maximum allowable deflection limits governed by beam clear span divided by 180 ($L/180$), guaranteeing operational safety for forklift operators.
Includes standard 12.5% impact allowance for side-by-side two-pallet placements. Special calculations are applied for seismic risk zones (INPRES-CIRSOC 103 / IBC).
RMI rated load capacity expressed in pounds (lbs) and kilograms (kg) per pair of beams based on undamaged components installed plumb.
| Beam Clear Length | Beam Profile & Gauge | Part Number Prefix | RMI Rated Capacity (Per Pair) | Max Allowable Deflection |
|---|---|---|---|---|
| 48″ (1,219 mm) | 3.56″ Profile – 16 Gauge | F2 / GF2 / TF2 | 7,991 lbs (3,624 kg) | 0.266″ (6.77 mm) |
| 60″ (1,524 mm) | 3.56″ Profile – 16 Gauge | F2 / GF2 / TF2 | 6,544 lbs (2,968 kg) | 0.333″ (8.46 mm) |
| 72″ (1,828 mm) | 3.56″ Profile – 16 Gauge | F2 / GF2 / TF2 | 5,573 lbs (2,527 kg) | 0.400″ (10.16 mm) |
| 96″ (2,438 mm) | 2.50″ Profile – 16 Gauge | F2 / GF2 / TF2 | 2,126 lbs (964 kg) | 0.533″ (13.54 mm) |
| 96″ (2,438 mm) | 3.56″ Profile – 16 Gauge | F2 / GF2 / TF2 | 3,972 lbs (1,801 kg) | 0.533″ (13.54 mm) |
| 96″ (2,438 mm) | 4.18″ Profile – 16 Gauge | F2 / GF2 / TF2 | 5,296 lbs (2,402 kg) | 0.533″ (13.54 mm) |
| 96″ (2,438 mm) | 5.00″ Profile – 16 Gauge | F2 / GF2 / TF2 | 6,730 lbs (3,052 kg) | 0.533″ (13.54 mm) |
| 96″ (2,438 mm) | 6.00″ Profile – 14 Gauge | F2 / GF2 / TF2 | 9,897 lbs (4,489 kg) | 0.533″ (13.54 mm) |
| 108″ (2,743 mm) | 4.18″ Profile – 16 Gauge | F2 / GF2 / TF2 | 4,431 lbs (2,009 kg) | 0.600″ (15.24 mm) |
| 108″ (2,743 mm) | 5.00″ Profile – 14 Gauge | F2 / GF2 / TF2 | 6,800 lbs (3,084 kg) | 0.600″ (15.24 mm) |
| 120″ (3,048 mm) | 4.50″ Profile – 16 Gauge | F2 / GF2 / TF2 | 4,254 lbs (1,929 kg) | 0.666″ (16.93 mm) |
| 120″ (3,048 mm) | 6.00″ Profile – 14 Gauge | F2 / GF2 / TF2 | 7,997 lbs (3,627 kg) | 0.666″ (16.93 mm) |
| 144″ (3,657 mm) | 5.00″ Profile – 14 Gauge | F2 / GF2 / TF2 | 4,192 lbs (1,901 kg) | 0.800″ (20.32 mm) |
| 144″ (3,657 mm) | 6.00″ Profile – 12 Gauge | F2 / GF2 / TF2 | 8,979 lbs (4,072 kg) | 0.800″ (20.32 mm) |
Designed for heavy industrial loading, freezer applications, and high-impact environments. Rated per pair of beams with and without mid-span lateral ties.
| Length | C3 x 3.5 (No Tie) | C3 x 3.5 (W/ Tie) | C4 x 4.5 (No Tie) | C4 x 4.5 (W/ Tie) | C6 x 8.2 (No Tie) | C6 x 8.2 (W/ Tie) |
|---|---|---|---|---|---|---|
| 48″ | 12,593 lbs | 12,858 lbs | 16,000 lbs | 16,000 lbs | 16,000 lbs | 16,000 lbs |
| 72″ | 7,577 lbs | 8,680 lbs | 10,801 lbs | 14,074 lbs | 16,000 lbs | 16,000 lbs |
| 96″ | 4,777 lbs | 5,068 lbs | 6,904 lbs | 10,263 lbs | 15,871 lbs | 16,000 lbs |
| 108″ | 3,821 lbs | 4,070 lbs | 5,541 lbs | 8,493 lbs | 12,344 lbs | 16,000 lbs |
| 120″ | 3,132 lbs | 3,345 lbs | 4,417 lbs | 6,928 lbs | 9,877 lbs | 16,000 lbs |
| 144″ | 2,220 lbs | 2,379 lbs | 3,070 lbs | 4,865 lbs | 6,729 lbs | 14,619 lbs |
Frame capacity is governed by the maximum vertical distance between beam levels (unsupported length). Figures are based on symmetrical axial loading per frame.
| Max Unsupported Length | 3″ x 1-5/8″ (14 Ga.) | 3″ x 3″ Open (13 Ga.) | 3″ x 3″ Open (10 Ga.) | SuperPost 3″x3″ Closed (12 Ga.) | 4″ x 3″ Closed (10 Ga.) |
|---|---|---|---|---|---|
| 36″ (914 mm) | 17,028 lbs | 32,722 lbs | 52,184 lbs | 51,476 lbs | 84,401 lbs |
| 48″ (1,219 mm) | 13,234 lbs | 26,028 lbs | 40,667 lbs | 46,644 lbs | 76,108 lbs |
| 60″ (1,524 mm) | 10,650 lbs | 21,347 lbs | 32,792 lbs | 34,747 lbs | 66,632 lbs |
| 72″ (1,828 mm) | 8,295 lbs | 17,035 lbs | 25,685 lbs | 26,519 lbs | 56,637 lbs |
| 84″ (2,133 mm) | 6,441 lbs | 13,315 lbs | 19,869 lbs | 19,582 lbs | 46,740 lbs |
| 96″ (2,438 mm) | 5,113 lbs | 10,628 lbs | 15,742 lbs | 14,993 lbs | 37,424 lbs |
Note: Frame load capacities assume undamaged, plumb installations with adequate concrete anchors (minimum 3,000 PSI concrete floor strength). If any of the following project conditions apply, direct technical review by Plata Metal Shelving S.A. engineering team is mandatory:
Published load tables assume a standard two-pallet placement per beam level. For three-pallet-wide beam levels, multiply rated capacities by 0.95 to account for load concentration. For single-pallet placement per shelf, apply a 0.90 multiplier.
Roll-formed step beams with clear spans exceeding 150 inches (3,810 mm) require mid-span lateral ties. Structural steel channel beams longer than 108 inches (2,743 mm) also require lateral ties to prevent torsional buckling under full load.
Yes. Plata Metal Shelving S.A. provides custom structural engineering stamps, site-specific anchor embedment calculations, and INPRES-CIRSOC 103 / RMI compliant dynamic load certifications for seismic zones across Latin America and international regions.
Consult directly with our structural engineering team at Plata Metal Shelving S.A. for certified load plaques and custom system design.
[email protected]